Datalogic DX6400 Installationshandbuch Seite 49

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 94
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 48
INSTALLATION
2
The following image shows a system consisting of six readers where:
the system is powered by the PWR-240
the master and all slaves are connected together through the CAB-610X cables
the external signals (trigger, encoder, serial to host, etc.) are connected to the master
through the C-BOX 100
one or more slaves are connected through CAB-63XX. The last slave must be terminated
with the BTK-6000
Master
Slave 2
Slave1
C-BOX 100**
BTK-6000
CAB-610X
CAB-610X
CAB-60XX
PS*
CAB-610X
Encoder***
Host
CAB-610X
CAB-610X
CAB-63XX
BTK-6000
PWR-240
Slave 5
Slave 3
Slave 4
CAB-63XX
* P.S. (Presence Sensor) connected to External Trigger/PS input.
** C-BOX 100 modified to accept scanner power
*** Encoder connected to IN2/ENC input.
Figure 44 – Small Synchronized Network with more than 2 Readers and Single Power Unit
NOTE
If a single power source is used, it is not necessary to separate groups of
scanners with "no power" cables (CAB-611X).
35
Seitenansicht 48
1 2 ... 44 45 46 47 48 49 50 51 52 53 54 ... 93 94

Kommentare zu diesen Handbüchern

Keine Kommentare