Dragon™ D131/M131Reference ManualAustraliaDatalogic Scanning Pty LtdNorth Ryde, AustraliaTelephone: [61] (2) 9870 3200Fax: [61] (2) 9878 8688France an
x OM-30X0 / C-3000 CRADLES Figure C – OM-3000 Figure D – C-3000 LEDs LEDs
90 DECODING PARAMETERS INK SPREAD OVERFLOW CONTROL INTERDIGIT CONTROL DECODING SAFETY PUZZLE SOLVER™ CAUTION Before chan
Enter Configuration Exit and Save Configuration Ì$+;Î DECODING PARAMETERS Ì$-?Î 91 INK SPREAD disable ÌAX0{Î enable ÌAX1~Î See par.
Enter Configuration Exit and Save Configuration Ì$+;Î DECODING PARAMETERS Ì$-?Î 92 DECODING SAFETY one read ÌED0WÎ (decoding safety disable
93 CODE SELECTION AUTO-CONFIGURATION EAN/UPC FAMILY 2/5 FAMILY CODE 39 FAMILY CODE 128 FAMILY CODABAR FAMILY CODE 93
94 Code selections may be performed according to two different procedures: - Auto-configuration, allowing an automatic recognition and selection o
Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 95 DISABLE ALL CODE FAMILIES ÌAZ0ÃÎ NOTE The reader allows up to
Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 96 EAN/UPC FAMILY disable the family ÌAA0MÎ Read the desired fa
Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 97 WITH ADD ON 2 ONLY EAN 8/EAN 13 ÌAAK7Î UPC A/UPC E ÌAAM=Î
Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 98 SELECT EAN/UPC PREFIXES NOTE When scanning the following codes,
Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 99 Example: The following string allows reading and transmitting wit
INTRODUCTION 1 1 INTRODUCTION Datalogic renews its range of industrial laser scanners introducing the Dragon™ family: Dragon™ Desk and Dragon™ Mob
Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 100 EAN/UPC CHECK DIGIT TX SELECTIONS For each code type in this fam
Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 101 CONVERSION OPTIONS UPC E to UPC A conversion ÌAAAÄÎ UPC
Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 102 2/5 FAMILY disable the family ÌAC0QÎ Read the desired famil
Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 103 CODE 39 FAMILY disables the family ÌAB0OÎ Read the desired
Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 104 CODE 128 FAMILY disables the family ÌAI0]Î Read the desired
Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 105 CODE 93 disables the code ÌAK0aÎ Code 93 ÌAK1dÎ contr
Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 106 Codabar ABC Forced Concatenation enable Codabar ABC with forced
Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 107 MSI disable the family ÌAE0UÎ Enable the code by selecting on
Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 108 CODE 11 disable the family ÌAG0YÎ Enable the code by selectin
Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 109 CODE 16K disable the code ÌAJ0_Î Code 16K ÌAJ1bÎ To read
DRAGON™ DX31/MX31 2 2 INSTALLATION CAUTION Connections should always be made with power OFF! 2.1 DRAGON™ DX31 INTERFACE CABLE CONNECTIONS T
Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 110 RSS CODES disable the family ÌAQ0mÎ DISABLE CODE disable RS
111 ADVANCED FORMATTING NOT FOR PEN INTERFACES CONCATENATION ADVANCED FORMATTING NOTE Please follow the setup procedure careful
Enter Configuration Exit and Save Configuration Ì$+;Î ADVANCED FORMATTING Ì$-?Î 112 CONCATENATION disable ÌEI0aÎ enable ÌEI1dÎ Permits
Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 113 2 Code 2 code ID ÌEK1hÎ Read the code type from the Code Identifier Table beg
Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 114 5 Transmission after Timeout no code transmitted after timeout ÌEM0iÎ only
ADVANCED FORMATTING 115 ADVANCED FORMATTING Advanced formatting has been designed to offer you complete flexibility in changing the format of
Enter Configuration Exit and Save Configuration Ì$+;Î ADVANCED FORMATTING Ì$-?Î 116 1 Begin Format Definition begin Format 1 definition
Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 117 4 Match with Predefined Characters no match ÌHD0HE00ÄÎ OR match with 1 c
Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 118 5 Divide Code into Fields divide code into fields ÌHF.Î Read one number in
Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 119 DEFINE FIELD 1 BY: EITHER field separator a) ÌHG0`Î Read the field separator ch
INSTALLATION 3 Follow the given procedure for correct cable insertion: Slip the cover over the cable. Push the rubber boot completely
Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 120 DEFINE FIELD 2 BY: EITHER field separator a) ÌHG0`Î Read the field separator ch
Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 121 DEFINE FIELD 3 BY: EITHER field separator a) ÌHG0`Î Read the field separator ch
Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 122 DEFINE FIELD 4 BY: EITHER field separator a) ÌHG0`Î Read the field separator ch
Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 123 DEFINE FIELD 5 BY: EITHER field separator a) ÌHG0`Î Read the field separator ch
Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 124 7 First Additional Fixed Field no fixed field ÌHI0dÎ 1 character fixed f
Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 125 8 Second Additional Fixed Field no fixed field ÌHJ0fÎ 1 character fixed
Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 126 9 Field Transmission number of fields to transmit ÌHK8Î Read one number in
Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 127 10 Standard Formatting do not apply standard formatting ÌHL0jÎ
Enter Configuration Exit and Save Configuration Ì$+;Î ADVANCED FORMATTING Ì$-?Î 128 Enable Advanced Format no Advanced Formats enabled Ì
Enter Configuration Exit and Save Configuration Ì$+;Î ADVANCED FORMATTING Ì$-?Î 129 No Match Result clear data - no transmission ÌHO0pÎ tran
DRAGON™ DX31/MX31 4 2.2 OM-30X0 INTERFACE CABLE CONNECTIONS OM-30X0 Connectors The OM-30X0 incorporates a multi-standard interface, which can
130 RADIO PARAMETERS Dragon™ M131 Series readers only RADIO PROTOCOL TIMEOUT POWER-OFF TIMEOUT TRANSMISSION MODE BEEPER CONTROL F
Enter Configuration Exit and Save Configuration Ì$+;Î RADIO PARAMETERS Ì$-?Î 131 RADIO PROTOCOL TIMEOUT radio protocol timeout ÌRH<Î Re
Enter Configuration Exit and Save Configuration Ì$+;Î RADIO PARAMETERS Ì$-?Î 132 TRANSMISSION MODE One Way ÌRI0nÎ Two-ways ÌRI1qÎ See par.
Enter Configuration Exit and Save Configuration Ì$+;Î RADIO PARAMETERS Ì$-?Î 133 SINGLE STORE disable ÌRO0zÎ one attempt two attemp
Enter Configuration Exit and Save Configuration Ì$+;Î RADIO PARAMETERS Ì$-?Î 134 BATCH MODE disable batch enable normal batch ÌBZ0ÄÎ
135 DISPLAY PARAMETERS Dragon™ M131 Series readers only DATE AND TIME CONTRAST FONT SIZE BACKLIGHT DISPLAY OFF TIMEOUT
Enter Configuration Exit and Save Configuration Ì$+;Î DISPLAY PARAMETERS Ì$-?Î 136 DATE AND TIME set date ÌIA%Î set time Read 6 numb
Enter Configuration Exit and Save Configuration Ì$+;Î DISPLAY PARAMETERS Ì$-?Î 137 DISPLAY-OFF TIMEOUT timeout ÌIF/Î Read 2 numbers in the r
Enter Configuration Exit and Save Configuration Ì$+;Î DISPLAY PARAMETERS Ì$-?Î 138 KEYPAD disable reader keypad ÌIK0iÎ enable reader
REFERENCES 139 5 REFERENCES 5.1 RS232 PARAMETERS 5.1.1 Handshaking Hardware handshaking: (RTS/CTS) The RTS line is activated by the decoder bef
INSTALLATION 5 2.3 RS232 CONNECTION 2.4 USB (if required)
DRAGON™ D131/M131 140 5.1.2 ACK/NACK Protocol Dragon™ D131 Readers This parameter sets a transmission protocol in which the Host responds to the rea
REFERENCES 141 OM-30X0 Host data cable DRAGON™ M data NACK ACK good RX beep Transmission Mode = Two-Ways data ACK/NACK enabled When ACK/NA
DRAGON™ D131/M131 142 5.1.4 RX Timeout When the RS232 interface is selected, the Host can be used to configure the device by sending it command stri
REFERENCES 143 5.2.3 Overflow This parameter generates a white space before the first bar and after the last bar of the code. The selections are a
DRAGON™ D131/M131 144 5.2.5 Inter-Block Delay For the PEN Emulation interface, data are sent to the Host in fixed size blocks of 20 characters each.
REFERENCES 145 The message is sent in the following format: "Message" CR LF 5.3.3 Reception Warning Message The Master cradle can tr
DRAGON™ D131/M131 146 These default values are always restored through the reading of RS232 or WEDGE interface selection code, see chapter 2. For the
Enter Configuration Ì$+;Î 147 5.4.2 Define Special Key Sequence The Special Key(s) for Wedge IBM AT-PS/2 and USB-KBD interface users can b
DRAGON™ D131/M131 148 2. Read only one code to be associated with the special key sequence: SHIFT Ì12Î OR CTRL Ì23Î OR ALT Ì45Î
Exit and Save Configuration Ì$-?Î 149 3. Select the character to be associated with the Special Key sequence by reading the codes correspond
DRAGON™ DX31/MX31 6 2.5 IBM USB POS (if required)
DRAGON™ D131/M131 150 ITA USA FR BE DE UK ES SW JP : 049 S 04C S 049 049 049 S 04C S 049 S 049 S 052 ; 041 S 04C 041 041 041 S 04C 041 S 041 S
REFERENCES 151 ITA USA FR BE DE UK ES SW JP w 01D 01D 01A 01A 01D 01D 01D 01D 01D x 022 022 022 022 022 022 022 022 022 y 035 035 035 035
DRAGON™ D131/M131 152 ITA USA FR BE DE UK ES SW JP Up arrow 275 275 275 275 275 275 275 275 275 Down arrow 272 272 272 272 272 272 272 272 272 Left
REFERENCES 153 2. the following example allows defining Special Key 2 as CTRL + S (upper case): enter configuration define Special Key 2 CTRL
DRAGON™ D131/M131 154 2. the following example allows setting Special Key 2 (defined in example 2 above) as header: enter configuration one chara
REFERENCES 155 5.4.5 Time Stamping Format The Time Stamping parameter sets the format for hour and date information. It consists of 1 or 2 groups
DRAGON™ D131/M131 156 5.5.2 Enter Sleep Timeout For readers that have the Sleep state enabled, this timeout determines when the reader will enter t
REFERENCES 157 When one read per cycle is selected, the device decodes only one code during the ON period and immediately turns the reader OFF. It
DRAGON™ D131/M131 158 5.7.3 Interdigit Control The interdigit control parameter verifies the interdigit spacing for code families Code 39 and Codab
REFERENCES 159 5.9.2 Power-Off Timeout If this command is enabled, after the desired timeout in hours, the Dragon™ batteries are disconnected and
INSTALLATION 7 2.6 WEDGE CONNECTION 2.7 PEN EMULATION CONNECTION
DRAGON™ D131/M131 160 With ACK/NACK disabled, the Host responds to the reader (through the cradle) with an answer message (message to reader display
REFERENCES 161 Conversely, if single store is disabled, and the user wants to retry transmission, the code must be read again, and therefore the at
DRAGON™ D131/M131 162 In batch mode, the selected Transmission Mode determines the behavior of the gun at the time the list of codes is transmitted.
REFERENCES 163 5.11 CONFIGURATION EDITING COMMANDS The following commands carry out their specific function and then exit the configuration enviro
DRAGON™ D131/M131 164 5.12 CUSTOM DEFAULT CONFIGURATION Read the following code to set the reader user-defined configuration as custom default confi
REFERENCES 165 5.14 CONFIGURATION COPYING COMMANDS 5.14.1 Copy Dragon™ D131 Series Procedure: Connect the master (correctly configured reader)
DRAGON™ D131/M131 166 5.14.2 Copy Dragon™ M131 Series Procedure: Using the slave reader and its OM-30X0 cradle, follow the initialization procedur
REFERENCES 167 5.14.3 Copy OM-30X0 Procedure: Using the slave reader and its OM-30X0 cradle, read the Restore Default barcode, set the radio add
DRAGON™ D131/M131 168 5.15 DEFAULT PARAMETERS FOR POS TERMINALS The default values of the RS232 and Data Format parameters for POS terminals are li
REFERENCES 169 5.16 FIRMWARE UPGRADE Device firmware upgrades can be performed using the Downloader utility tool (downloadable from the web site:
DRAGON™ DX31/MX31 8 2.8 NETWORK CONNECTIONS 2.8.1 OM3000 Network Connectors The multidrop network is a bus system which is propagated from one
DRAGON™ D131/M131 170 6 MESSAGE FORMATTING The system always provides gun to host data communication using the following message formatting: Outpu
MESSAGE FORMATTING 171 • If you have not enabled the Gun Address Stamping or the Gun Address Delimiter, you must not specify them. In this case al
DRAGON™ D131/M131 172 • The cursor row position is not affected by the currently selected font. The display always has 4 rows, so when writing wit
MESSAGE FORMATTING 173 The LED control escape sequences are intended to activate the LEDs for short periods of time and can be used in combination
DRAGON™ D131/M131 174 The default characters associated with each key (KeyID) are shown in the following table: Default Key Identifiers Key KeyID ▲
TECHNICAL FEATURES 175 7 TECHNICAL FEATURES 7.1 DRAGON™ D131 Electrical Features Supply Voltage 4 to 30 Vdc Consumption @ 4V @ 5V @ 30 V Sleep
DRAGON™ D131/M131 176 7.2 DRAGON™ M131 Electrical and General Features Battery Type 2150 Li-Ion battery pack Recharge Time max. 4 hours with exter
TECHNICAL FEATURES 177 7.3 OM-30X0 / C-3000 OM-30X0 C-3000 Electrical and General Features Supply Voltage External Power 10 to 30 Vdc Hos
DRAGON™ D131/M131 178 7.4 SYSTEM AND RADIO FEATURES Radio Features European Models USA Models Working Frequency 433.92 MHz 910 MHz Bit Rate 192
TECHNICAL FEATURES 179 Dragon™ D131/M131 READER DATA ENTRY Beeper¹ LED Good Read Spot Meaning one beep² ON ON Correct read of a code in normal
INSTALLATION 9 2.8.2 Network Cabling The Multidrop line is made using RJ45 connectors and a cable having the following specifications: • twisted p
DRAGON™ D131/M131 180 OM-30X0/C-3000 POWER/COMMUNICATION Aux LED Host LED Yellow Yellow Meaning OFF OFF Device off ON Power applied through an e
TECHNICAL FEATURES 181 7.6 READING DIAGRAMS DRAGON™ D/M131 12 24 36 48 6096 36 24 12 0 12 24 36 cm 72 84108 cm 0.19 mm (7.5 mils) 0.25 mm(10 mils
DRAGON™ D131/M131 182 A HOST CONFIGURATION STRINGS In this section we provide a description of how to modify the device configuration using serial
HOST CONFIGURATION STRINGS 183 SERIAL CONFIGURATION STRINGS SPECIAL CONFIGURATION COMMANDS DESCRIPTION STRING Enter Configuration $+ Exit and Sav
DRAGON™ D131/M131 184 RS232 DESCRIPTION STRING Baud Rate 300 CD1 600 CD2 1200 CD3 2400 CD4 4800 CD5 9600 CD6 19200 CD7 38400 CD8 Pari
HOST CONFIGURATION STRINGS 185 USB DESCRIPTION STRING USB-COM Handshaking disable CE0 RTS/CTS CE1 XON/XOFF CE2 RTS always ON CE3 ACK/NACK
DRAGON™ D131/M131 186 WEDGE DESCRIPTION STRING Keyboard Nationality Belgian FJ7 English FJ4 French FJ2 German FJ3 Italian FJ1 Spanish FJ6
HOST CONFIGURATION STRINGS 187 PEN (continued) DESCRIPTION STRING Idle Level normal DE0 inverted DE1 Overflow narrow overflow DH0 medium over
DRAGON™ D131/M131 188 DATA FORMAT NOT FOR PEN EMULATION INTERFACES DESCRIPTION STRING Code Identifier disable EB0 Datalogic standard EB1 AIM sta
HOST CONFIGURATION STRINGS 189 DATA FORMAT (continued) NOT FOR PEN EMULATION INTERFACES DESCRIPTION STRING Code Length Tx not transmitted EE0 t
Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights r
DRAGON™ DX31/MX31 10 2.8.3 Network Termination The first and last cradles of the chain (the two ends of the bus) must be properly terminated. The
DRAGON™ D131/M131 190 POWER SAVE DESCRIPTION STRING Sleep State disable BQ0 (only for D131 series) enable BQ1 Enter Sleep Timeout (100 ms) BR00-B
HOST CONFIGURATION STRINGS 191 DECODING PARAMETERS DESCRIPTION STRING Ink-spread disable AX0 enable AX1 Overflow Control disable AW1 enable
DRAGON™ D131/M131 192 CODE SELECTION (continued) DESCRIPTION STRING UPC A check digit transmission disable AAI0 enable AAI1 UPC E check dig
HOST CONFIGURATION STRINGS 193 CODE SELECTION (continued) DESCRIPTION STRING Codabar disable Codabar family AD0 Standard no start/stop charact
DRAGON™ D131/M131 194 CODE SELECTION (continued) DESCRIPTION STRING Code 11 disable the family AG0 no check AG1 Type C with tx AG21 Type C n
HOST CONFIGURATION STRINGS 195 DISPLAY PARAMETERS DESCRIPTION STRING Date IAddmmyy Time IBhhmm lighter IC0 Contrast darker IC1 small ID0 medi
DRAGON™ D131/M131 196 B CODE IDENTIFIER TABLE 2/5 Interleaved ÌNOÎ 2/5 Industrial 2/5 normal 5 bars ÌPQÎ ÌOPÎ 2/5 matrix 3 bars EAN 8 ÌQRÎ ÌABÎ EA
CODE IDENTIFIER TABLE 197 UPC A with 5 ADD ON ÌGHÎ UPC E with 2 ADD ON UPC E with 5 ADD ON ÌHIÎ ÌIJÎ Code 39 Code 39 Full ASCII ÌVWÎ ÌWXÎ CODABAR A
DRAGON™ D131/M131 198 MSI ÌZ[Î Code 16K Code 11 ÌpqÎ ÌbcÎ Code 49 RSS Expanded Linear and Stacked ÌqrÎ ÌtuÎ RSS Limited RSS 14 Linear and Stacked Ìvw
HEX AND NUMERIC TABLE 199 C HEX AND NUMERIC TABLE CHARACTER TO HEX CONVERSION TABLE char hex char hex char hex NUL 00 * 2A U 55 SOH 01 +
INSTALLATION 11 2.9 DRAGON™ MX31 BATTERY MAINTENANCE 2.9.1 Battery Charging Once the system is connected and powered, you can place the Dragon™
Dragon™ D131/M131Reference ManualAustraliaDatalogic Scanning Pty LtdNorth Ryde, AustraliaTelephone: [61] (2) 9870 3200Fax: [61] (2) 9878 8688France an
DRAGON™ DX31/MX31 12 2.10 MOUNTING THE OM-30X0 / C-3000 CRADLE The cradle package contains the following items: OM-30X0 / C-3000 Cradle OM-30X
INSTALLATION 13 2.10.1 Desktop mounting For desktop usage, you can mount the cradle either on the horizontal base, for reduced overall dimensions,
DRAGON™ DX31/MX31 14 Portable Desktop Use 1. Correctly position the OM-30X0/C-3000 onto the base by sliding it along the mounting tabs until ali
INSTALLATION 15 4. Position the cables to be connected to the OM-30X0/C-3000 cradle along the dedicated channels, as shown in the figures below:
DRAGON™ DX31/MX31 16 2.10.2 Wall Mounting 1. Remove the yellow caps and insert the two wall mounting lock hinges provided with your cradle.
INSTALLATION 17 If using the adhesive strips: 3. Carefully clean the adhesive strip seats of the base to remove any impurities that could reduce a
DRAGON™ D131/M131 18 3 DRAGON™ M131 SYSTEM AND NETWORK LAYOUTS There are two basic system layouts that can be employed: Stand Alone systems (incl
DRAGON™ M131 SYSTEM AND NETWORK LAYOUTS 19 3.1.3 Multiple Stand Alone Layouts Many stand alone connections can operate in the same physical area w
iii CONTENTS GENERAL VIEW ... ix 1 INTRODUCTION ...
DRAGON™ D131/M131 20 3.1.4 C-BOX Layout In this layout the OM-30X0 cradle is connected by a dedicated cable using the RS232 interface to a C-B
DRAGON™ M131 SYSTEM AND NETWORK LAYOUTS 21 3.2 MULTIDROP STAR-SYSTEM™ NETWORK LAYOUTS Even though many stand alone systems can operate in the same
DRAGON™ D131/M131 22 3.2.2 OM-3000 Master Layout A. Host B. OM-3000 Master cradle C. OM-3000 Slave cradles D. STARGATE™ base station Exampl
DRAGON™ M131 SYSTEM AND NETWORK LAYOUTS 23 3.2.3 Master OM-3000 Network Troubleshooting Two diagnostic strings can be sent via RS232 from the Host
DRAGON™ D131/M131 24 4 CONFIGURATION 4.1 CONFIGURATION METHODS 4.1.1 Reading Configuration Barcodes This manual can be used for complete setup an
CONFIGURATION 25 4.1.4 Sending Configuration Strings from Host An alternative configuration method is provided in Appendix A using the RS232 interfa
DRAGON™ D131/M131 26 4.3 DRAGON™ D131 SETUP 1. Read the restore default parameters code below. Restore Dragon™ D131 Default Ì$+$*oÎ After reading
CONFIGURATION 27 4.5 DRAGON™ M131/OM-30X0 STAND ALONE SETUP Read the restore default parameters code below. Restore Dragon™M131 Default 1. Ì$+$*o
DRAGON™ D131/M131 28 Set Radio Address 5. ÌRA0RFHÎ + four digits for the Dragon™ M131 Address (from 0000 to 1999). All readers used in the same a
CONFIGURATION 29 Read the OM-30X0 restore default code: 9. Restore OM-30X0 Default Ì$+RX0$-qÎ Go to par. 4.8 Interface Selection. 4.5.1 Usin
iv 4.5 Dragon™ M131/OM-30X0 Stand Alone Setup... 27 4.5.1 Using Multiple M-Series Readers With Same Cradl
DRAGON™ D131/M131 30 4.5.2 Dragon™ M131/STAR-Modem™ in Stand Alone Mode To configure a Dragon™ M131 reader to communicate with STAR-Modem™ in Stand
CONFIGURATION 31 4.6 DRAGON™ M/STAR-SYSTEM™ SETUP The following procedure allows configuring a Dragon™ M131 reader to communicate with various STAR
DRAGON™ D131/M131 32 Set Radio Address 6. ÌRF8Î + four digits from the Numeric Table in the range 0000-1999. All readers must have different address
CONFIGURATION 33 4.7 OM-3000 STAR-SYSTEM™ NETWORK SETUP When the OM-3000 cradle model is used in an RS485 network, it must be initially configured.
DRAGON™ D131/M131 34 Read the OM-3000 restore default code: 5. Restore OM-3000 Default Ì$+RX0$-qÎ Read the desired Enable Network code. Enable
CONFIGURATION 35 4.8 INTERFACE SELECTION Read the interface selection code for your application. RS232 Standard Ì$+CP0$-$Î POS TERMINALS Nix
DRAGON™ D131/M131 36 WEDGE IBM AT or PS/2 PCs Ì$+CP500$-aÎ IBM XT PC Notebook Ì$+CP503$-vÎ Ì$+CP505$-ÈÎ IBM SURE1 IBM Terminal 315
CONFIGURATION 37 WEDGE (CONTINUED) ALT MODE The ALT-mode selection allows barcodes sent to the PC to be interpreted correctly independently from th
DRAGON™ D131/M131 38 WEDGE (CONTINUED) DIGITAL TERMINALS VT2xx/VT3xx/VT4xx Ì$+CP512$-uÎ APPLE APPLE ADB Bus Ì$+CP513$-|Î
CONFIGURATION 39 4.9 USB READER CONFIGURATION The USB interface is available for Dragon D131, OM-30x0 and C-3000 devices and is compatible with the
v Minimum Output Pulse... 62 Conversion to Code 39 (D131 Series Only)..
DRAGON™ D131/M131 40 USB USB-KBD Ì$+UA03$-:Î USB-KBD-ALT-MODE Ì$+UA04$-@Î USB-KBD-APPLE Ì$+UA05$-FÎ USB-COM* Ì$+UA02$-4Î USB-IBM-Table
CONFIGURATION 41 4.10 CHANGING DEFAULT SETTINGS Once your reader is setup, you can change the default parameters to meet your application needs. Re
42 RS232 PARAMETERS All Dragon™ D131 Series readers + Dragon™ M131/OM-30X0 configurations only BAUD RATE PARITY DATA BITS STOP BIT
Enter Configuration Exit and Save Configuration Ì$+;Î RS232 Ì$-?Î 43 BAUD RATE 300 baud ÌCD1XÎ 600 baud 1200 baud ÌCD2[Î ÌCD3^Î
Enter Configuration Exit and Save Configuration Ì$+;Î RS232 Ì$-?Î 44 DATA BITS 7 bits ÌCA0OÎ 8 bits 9 bits ÌCA1RÎ ÌCA2UÎ STOP
Enter Configuration Exit and Save Configuration Ì$+;Î RS232 Ì$-?Î 45 ACK/NACK PROTOCOL disable ÌER0sÎ enable ÌER1vÎ See par. 5.1.2
Enter Configuration Exit and Save Configuration Ì$+;Î RS232 Ì$-?Î 46 RX TIMEOUT timeout control in reception from Host ÌCL5Î Read 2 numbers fr
47 USB PARAMETERS USB-COM Handshaking, Ack/Nack protocol, FIFO, Inter-character delay, Rx timeout, Serial trigger lock USB-KBD Keyboard na
Enter Configuration Exit and Save Configuration Ì$+;Î USB-COM Ì$-?Î 48 HANDSHAKING disable ÌCE0WÎ hardware (RTS/CTS) software (XON/
Enter Configuration Exit and Save Configuration Ì$+;Î USB-COM Ì$-?Î 49 INTER-CHARACTER DELAY delay between characters transmitted to Host ÌCK3Î
vi Beeper Type ... 88 Beeper Length ...
Enter Configuration Exit and Save Configuration Ì$+;Î USB-KBD Ì$-?Î 50 KEYBOARD NATIONALITY Not Available for USB-KBD-ALT-MODE Interface This p
Enter Configuration Exit and Save Configuration Ì$+;Î USB-KBD Ì$-?Î 51 The Japanese and Eastern Block Keyboard Nationality selections are valid
Enter Configuration Exit and Save Configuration Ì$+;Î USB-KBD Ì$-?Î 52 INTER-CHARACTER DELAY delay between characters transmitted to Host ÌCK3Î
53 WEDGE PARAMETERS All Dragon™ D131 Series readers + Dragon™ M131/OM-30X0 configurations only KEYBOARD NATIONALITY CAPS LOCK CAPS LOC
Enter Configuration Exit and Save Configuration Ì$+;Î WEDGE Ì$-?Î 54 KEYBOARD NATIONALITY Belgian ÌFJ7yÎ English French ÌFJ4pÎ ÌFJ2jÎ
Enter Configuration Exit and Save Configuration Ì$+;Î WEDGE Ì$-?Î 55 The Japanese and Eastern Block Keyboard Nationality selections are valid on
Enter Configuration Exit and Save Configuration Ì$+;Î WEDGE Ì$-?Î 56 CAPS LOCK AUTO-RECOGNITION (IBM AT COMPATIBLE ONLY) disable ÌFP0pÎ
Enter Configuration Exit and Save Configuration Ì$+;Î WEDGE Ì$-?Î 57 INTER-CODE DELAY delay between codes transmitted to Host ÌFG.Î Read 2 num
WEDGE 58 Some ASCII characters may be missing as this depends on the type of keyboard: these are generally particular characters relative to t
Enter Configuration Exit and Save Configuration Ì$+;Î WEDGE Ì$-?Î 59 CONTROL CHARACTER EMULATION Ctrl + Shift + Key ÌFO0nÎ Ctrl + Key
vii Keypad... 138 5 REFERENCES ...
60 PEN EMULATION All Dragon™ D131 Series readers + Dragon™ M131/OM-30X0 configurations only OPERATING MODE MINIMUM OUTPUT PULSE CONVER
PEN EMULATION 61 The operating mode parameters are complete commands and do not require reading the Enter and Exit configuration codes. OPE
Enter Configuration Exit and Save Configuration Ì$+;Î PEN EMULATION Ì$-?Î 62 MINIMUM OUTPUT PULSE 200 µs ÌDG0\Î 400 µs 600
Enter Configuration Exit and Save Configuration Ì$+;Î PEN EMULATION Ì$-?Î 63 CONVERSION TO CODE 39 (D131 SERIES ONLY) disable conversion to C
Enter Configuration Exit and Save Configuration Ì$+;Î PEN EMULATION Ì$-?Î 64 See par. 5.2.3 for details. OUTPUT LEVEL normal ÌDD0VÎ (whit
65 NETWORK PARAMETERS OM-3000 model configurations only RS485 NETWORK NETWORK BAUD RATE SLAVE ADDRESS RANGE NETWORK WARNING MESSAG
Enter Configuration Exit and Save Configuration Ì$+;Î NETWORK PARAMETERS Ì$-?Î 66 RS485 NETWORK disable RS485 network ÌRZ0)Î enable RS
Enter Configuration Exit and Save Configuration Ì$+;Î NETWORK PARAMETERS Ì$-?Î 67 SLAVE ADDRESS RANGE First Address ÌJB(Î Read the code above
Enter Configuration Exit and Save Configuration Ì$+;Î NETWORK PARAMETERS Ì$-?Î 68 MASTER CRADLE HEADER no header ÌJA00/Î one charac
Enter Configuration Exit and Save Configuration Ì$+;Î NETWORK PARAMETERS Ì$-?Î 69 MASTER CRADLE TERMINATOR no terminator ÌJA102Î on
viii 5.9.5 Single Store ... 160 5.9.6 Batch Mode...
70 DATA FORMAT NOT FOR PEN INTERFACES CODE IDENTIFIER CUSTOM CODE IDENTIFIER HEADER TERMINATOR SPECIAL KEYS FIELD ADJUSTME
DATA FORMAT 71 CODE IDENTIFIER TABLE CODE AIM STANDARD DATALOGIC STANDARD Custom 2/5 interleaved ] I y N 2/5 industrial ] X y P 2/5 n
Enter Configuration Exit and Save Configuration Ì$+;Î DATA FORMAT Ì$-?Î 72 CODE IDENTIFIER disable ÌEB0SÎ Datalogic standard AIM st
Enter Configuration Exit and Save Configuration Ì$+;Î DATA FORMAT Ì$-?Î 73 HEADER no header ÌEA00*Î one character header two char
Enter Configuration Exit and Save Configuration Ì$+;Î DATA FORMAT Ì$-?Î 74 TERMINATOR no terminator ÌEA10-Î one character terminator
Enter Configuration Exit and Save Configuration Ì$+;Î DATA FORMAT Ì$-?Î 75 SPECIAL KEYS Available only for Wedge IBM AT-PS/2 and USB-KBD Interf
Enter Configuration Exit and Save Configuration Ì$+;Î DATA FORMAT Ì$-?Î 76 FIELD ADJUSTMENT disable field adjustment ÌEF0[Î Field adjustment
Enter Configuration Exit and Save Configuration Ì$+;Î DATA FORMAT Ì$-?Î 77 FIELD ADJUSTMENT CHARACTER Read the field adjustment character c
Enter Configuration Exit and Save Configuration Ì$+;Î DATA FORMAT Ì$-?Î 78 CHARACTER REPLACEMENT disable character replacement ÌEO0mÎ This p
Enter Configuration Exit and Save Configuration Ì$+;Î DATA FORMAT Ì$-?Î 79 Example: The following strings define: 1. First Character Replacem
ix GENERAL VIEW DRAGON™ D131/M131 READERS Figure A – DRAGON™ D131 and M131 Series Readers Figure B – DRAGON™ M131 Series Readers with Display
Enter Configuration Exit and Save Configuration Ì$+;Î DATA FORMAT Ì$-?Î 80 ADDRESS STAMPING (M131 SERIES ONLY) disable reader address stampi
Enter Configuration Exit and Save Configuration Ì$+;Î DATA FORMAT Ì$-?Î 81 TIME STAMPING (M131 SERIES ONLY) disable ÌIL0kÎ hour/minutes/
82 POWER SAVE SLEEP STATE ENTER SLEEP TIMEOUT 1. Read the Enter Configuration code ONCE, available at the top of each
Enter Configuration Exit and Save Configuration Ì$+;Î POWER SAVE Ì$-?Î 83 SLEEP STATE disable ÌBQ0nÎ enable ÌBQ1qÎ See par. 5.5.1 f
84 READING PARAMETERS TRIGGER TYPE TRIGGER SIGNAL TRIGGER CLICK TRIGGER-OFF TIMEOUT FLASH MODE READS PER CYCLE SAFETY T
Enter Configuration Exit and Save Configuration Ì$+;Î READING PARAMETERS Ì$-?Î 85 TRIGGER TYPE hardware trigger ÌBK1eÎ Restores TRIGGER MOD
Enter Configuration Exit and Save Configuration Ì$+;Î READING PARAMETERS Ì$-?Î 86 TRIGGER-OFF TIMEOUT trigger-off timeout ÌBD$Î Read 2 numbers
Enter Configuration Exit and Save Configuration Ì$+;Î READING PARAMETERS Ì$-?Î 87 SAFETY TIME safety time ÌBE&Î Limits same code consecutiv
Enter Configuration Exit and Save Configuration Ì$+;Î READING PARAMETERS Ì$-?Î 88 BEEPER TONE tone 1 ÌBH0\Î tone 2 tone 3 ÌBH1_Î ÌB
Enter Configuration Exit and Save Configuration Ì$+;Î READING PARAMETERS Ì$-?Î 89 GOOD READ SPOT DURATION disable ÌBV0xÎ short medi
Kommentare zu diesen Handbüchern