PARAMETERS LIST
63
4
PARAMETER COMPLETE PATH SHC PT VALUE
Alternative Activation
Event
/IO/Relays/Relay1
/Active1
- 1 0 = None
1 = Complete Read
2 = Partial Read
3 = No Read
5 = Phase On
6 = Phase Off
8 = Multiple Read
Deactivation Event /IO/Relays/Relay1
/Deactive
- 1 0 = None
7 = Timeout
5 = Phase On
6 = Phase Off
Alternative Deactivation
Event
/IO/Relays/Relay1
/Deactive1
- 1 0 = None
5 = Phase On
6 = Phase Off
Activate On Error /IO/Relays/Relay1
/ActiveDiagnoErr
- 1 0 = Disable
1 = Any Diagnostic
Error
2 = PS or Encoder Error
Deactivate When Errors
Recovered
/IO/Relays/Relay1
/DeactiveDiagnoNoErr
- 1 0 = Disable
1 = All Diagnostic
Errors Recovered
2 = PS and Encoder
Errors Recovered
Deactivation Timeout
(ms)
/IO/Relays/Relay1
/Timeout
- 0 Range: 500 to 15000
RELAYS / RELAY 3
Line State /IO/Relays/Relay2
/Idle
- 1 0 = Normally Open
1 = Normally Closed
Activation Event /IO/Relays/Relay2
/Active
- 1 0 = None
1 = Complete Read
2 = Partial Read
3 = No Read
5 = Phase On
6 = Phase Off
8 = Multiple Read
Alternative Activation
Event
/IO/Relays/Relay2
/Active1
- 1 0 = None
1 = Complete Read
2 = Partial Read
3 = No Read
5 = Phase On
6 = Phase Off
8 = Multiple Read
Deactivation Event /IO/Relays/Relay2
/Deactive
- 1 0 = None
7 = Timeout
5 = Phase On
6 = Phase Off
Alternative Deactivation
Event
/IO/Relays/Relay2
/Deactive1
- 1 0 = None
5 = Phase On
6 = Phase Off