PARAMETERS LIST
27
4
PARAMETER COMPLETE PATH SHC PT VALUE
Minimum Pack
Length (mm)
/Operating
/PktrMinLen
209 0 Range: 50 to 1000
Window Dimension
(mm)
/Operating
/PktrWinDim
210 0 Range: 0 to 1000
Encoder Delay Error
Behaviour
/Operating
/PktrEncErr
214 1 0 = Ignore Error
1 = Fast Resync
2 = Safe Resync
Max. Encoder Delay
For Code
/Operating
/PktrEncMaxDelay
213 0 Range: 50 to 100000
Max. Consecutive
Delayed Codes For
Node
/Operating
/PktrMaxDelayOfCode
- 0 Range: 0 to 255
Max. Safe Resync
For Node
/Operating
/PktrMaxNodeResync
- 0 Range: 0 to 255
Bidirectional /Operating
/Bidirectional
- 1 0 = Disable
1 = Enable
Direction Input /Operating
/PktrInDir
- 1 1 = PS
3 = PSAUX
4 = Input_1
5 = Input_2
6 = Input_3
Reverse Direction
Level
/Operating
/PktrInDirLev
- 1 0 = Closed
1 = Open
Reverse Presence
Sensor Input
/Operating
/PktrPsRev
- 1 1 = PS
3 = PSAUX
4 = Input_1
5 = Input_2
6 = Input_3
Reverse Presence
Sensor Input Level
/Operating
/PktrPsRevLev
- 1 0 = Active Closed
1 = Active Open
Distance from PS to
Reverse PS (mm)
/Operating
/PktrRevOffsY
- 0 Range: 100 to 20000
Start Input from Bus
(Profibus Models
Only)
/Operating
/PbusOnl
- 1 0 = Disable
1 = Enable
Start Input from Bus
(Ethernet Models
Only)
/Operating
/EthOnl
- 1 0 = Disable
1 = Enable
Use Encoder
(Continuous Mode
Only)
/Operating
/ContOpt
- 1 0 = Disable
1 = Physical Encoder
2 = Auto Encoder
Encoder Step
(hundredths of
millimeter)
/Operating
/ContEncEncStep
- 0 Range: 1 to 10000
Conveyor Speed
(mm/sec)
/Operating
/ContEncSpeed
- 0 Range: 50 to 10000
Encoder Delay Error
Behaviour
/Operating
/ContEncErr
- 1 0 = Ignore Error
1 = Fast Resync
2 = Safe Resync
Max. Encoder Delay
For Code
/Operating
/ContEncMaxDelay
- 0 Range: 50 to 10000