PARAMETERS LIST
25
4
PARAMETER COMPLETE PATH SHC PT VALUE
Max Code Position /Codes
/Code#N
/MaxCodePos
263 0 Range: 0 to 255
Check Digit /Codes
/Code#N
/CheckDigit
5 1 0 = Disable
1 = Enable
Check Digit
Transmission
/Codes
/Code#N
/CheckDigitTx
524 1 0 = Disable
1 = Enable
Match String Rule /Codes
/Code#N
/MatchStrRule
- 1 0 = Match
1 = Do Not Match
Pattern Match String /Codes
/Code#N
/PatMatch
- 3 Length: 0 to 200
Code Label Local No
Read String
/Codes
/Code#N
/LocNoRead
18 3 Length: 0 to 48
Code Label Local
Multiple Read String
/Codes
/Code#N
/LocMulRead
328 3 Length: 0 to 48
Start Character
Transmission
(only for Codabar)
/Codes
/Code#N
/StartChTx
382 1 0 = Disabled
2 = Lower Case
3 = Upper Case
Stop Character
Transmission
(only for Codabar)
/Codes
/Code#N
/StopChTx
383 1 0 = Disabled
2 = Lower Case
3 = Upper Case
4.2 OPERATING MODES
PARAMETER COMPLETE PATH SHC PT VALUE
OPERATING MODES
Operating Mode
Selection
/Operating
/Selection
31 1 0 = On Line
4 = Continuous
5 = PackTrack
On Line Options /Operating
/OnLOpt
73 1 0 = On Line 1 input
1 = On Line 2 input
2 = Serial On Line
Extended Phase /Operating
/ExtendedPhase
- 1 0 = Disable
1 = Enable
Serial Start String /Operating
/SerialStart
86 3 Length: 1 to 32
Start Input Number /Operating
/ONLStartIn
74 1 1 = PS
3 = PSAUX
4 = Input_1
5 = Input_2
6 = Input_3
Start Input Active
Level
/Operating
/ONLStartInLev
75 1 0 = Active Closed
1 = Active Open