2KN FAMILY AND DS4800
4
PARAMETER COMPLETE PATH SHC PT VALUE
Mode /Comms
/CBXGateway
/FieldbusOptions
/BusData
/Mode
5422 1 0 = RTU
1 = ASCII
Connection Timeout
sec
/Comms
/CBXGateway
/FieldbusOptions
/ConnectionTimeout
/BusData
5423 0 Range: 0 to 65535
FIELDBUS / BUS COMMUNICATION / COMMUNICATION SETTING
Baud Rate /Comms
/CBXGateway
/FieldbusOptions
/BusData/Line
/Baud
5418 1 0 = 1200
4 = 2400
8 = 4800
12 = 9600
16 = 19200
24 = 38400
28 = 57600
32 = 115200
Parity /Comms
/CBXGateway
/FieldbusOptions
/BusData/Line
/Par
5419 1 0 = Even
1 = Odd
2 = None
Stop Bits /Comms
2 = 2 /CBXGateway
/FieldbusOptions
/BusData/Line
/Stopbit
5420 1 1 = 1
FIELDBUS / DIGITAL I/O CONDITIONING / DIGITAL INPUT LINES
Input 1 Echo /Comms 0 = Disable
/CBXGateway
/FieldbusOptions
/IO/In
/Input1
5298 1
1 = Enable
Input 2 Echo /Comms
/CBXGateway
/FieldbusOptions
/IO/In
/Input2
5299 1 0 = Disable
1 = Enable