2KN FAMILY AND DS4800 PARAMETERS LIST
4
4.5 READING PARAMETERS
PARAMETER COMPLETE PATH SHC PT VALUE
READING PARAMETERS
Scan Speed
(DS2100N-x2x0
models)
/Reading
/ScanSpeed_2100std
5020 1 1 = Off
2 = 500 (Default)
3 = 800
Scan Speed
(DS2100N-x2x4
models)
/Reading
/ScanSpeed_2100tr
5021 1 1 = Off
3 = 800
4 = 1000
Scan Speed
(DS2400N-x2x0
models)
/Reading
/ScanSpeed_2400
5022 1 1 = Off
2 = 600
3 = 800
4 = 1000
Scan Speed
(DS4800 models)
/Reading
/ScanSpeed_4800
5252 1 0 = Off
60 = 600
70 = 700
80 = 800 (Default)
90 = 900
Energy Saving /Reading
/EnergySavingEnab
5129 1 0 = Disable
1 = Enable
Serial Motor ON
String
/Reading
/SerialMotorOn
5133 3 Length: 0 to 32
Serial Motor OFF
String
/Reading
/SerialMotorOff
5132 3 Length: 0 to 32
Code Resolution /Reading
/CodeResolution
5024 1 0 = Standard
1 = High
2 = Toggle
Reading Conditions
(DS2100N and
DS2400N models)
/Reading
/ReadingConditions
5023 1 0 = Standard
1 = Difficult
2 = Toggle (Standard/
Difficult)
3 = Dark Background
4 = Toggle (Standard/
Dark Background)
5 = Toggle (Difficult/
Dark Background)
6 = Toggle All (Standard/
Difficult/ Dark
Background)
Reading Conditions
(DS4800 models)
/Reading
/ReadingConditions4K
5250 1 0 = Standard (Default)
1 = Cartons
2 = Low Contrast
3 = High Skew Angles
39