14
2
The Ethernet interface (NIC) can be used for TCP/IP communication with a remote or local
host computer by connecting the SC6000 Controller to a LAN or directly to a host PC.
The following is an example of a connection to a LAN through a Hub using a straight through
cable:
SC6000
5
HUB / SWITCH
3
4
2
1
6
5
3
4
2
1
6
7
8
7
8
RX+
TX-
TX+
RX-
n. c.
n. c.
n. c.
n. c.
n. c. = not connected
Figure 18 – Straight Through Cable
The following is an example of direct connection to a PC using an inverted cable:
SC6000
5
Host PC
3
4
2
1
6
5
1
4
6
3
2
7
8
7
8
RX+
TX-
TX+
RX-
n. c.
n. c.
n. c.
n. c.
n. c. = not connected
Figure 19 – Inverted Cable
For further details refer to the “Ethernet Service Guide” document provided as reference
documentation.