MATRIX 210™ HOST MODE PROGRAMMING
48
4
PARAMETER TYPE SEL STRING DATA
GS1 DataBar Limited 2 <ESC> L s Length: 0 to 32
GS1 DataBar 2 <ESC> L t Length: 0 to 32
GS1 DataBar Stacked 2 <ESC> L u Length: 0 to 32
Code 128 of Composite 2 <ESC> L L Length: 0 to 32
GS1 DataBar
Expanded of
Composite
2 <ESC> L M Length: 0 to 32
GS1 DataBar
Expanded Stacked of
Composite
2 <ESC> L z Length: 0 to 32
GS1 DataBar Limited of
Composite
2 <ESC> L N Length: 0 to 32
GS1 DataBar of
Composite
2 <ESC> L O Length: 0 to 32
GS1 DataBar Stacked
of Composite
2 <ESC> L P Length: 0 to 32
CC-A of Composite 2 <ESC> L Q Length: 0 to 32
CC-B of Composite 2 <ESC> L R Length: 0 to 32
CC-C of Composite 2 <ESC> L S Length: 0 to 32
Pharmacode 2 <ESC> L a Length: 0 to 32
MSI 2 <ESC> L < Length: 0 to 32
Standard 2 of 5 2 <ESC> L - Length: 0 to 32
Matrix 2 of 5 2 <ESC> L [ Length: 0 to 32
Code 32 2 <ESC> L _ Length: 0 to 32
DATA TRANSMISSION
Partial Read TX 1 1 <ESC> K L 0 = Disabled
1 = Enabled
Message TX Selection 1 1 <ESC> K M 0 = On Complete Read
1 = After Reading Phase OFF
2 = Delayed TX Line
3 = Delayed TX Line On Input
Reference Input Signal 4 4 <ESC> K T 1 = Ext. Trigger Leading Edge
2 = Ext. Trigger Trailing Edge
4 = Input 2 Leading Edge
8 = Input 2 Trailing Edge
Conveyor Speed
(mm/sec)
0 <ESC> K V Range: 50 to 10000
Delayed TX Line
Distance (mm)
0 <ESC> K Z Range: 100 to 20000
Physical Encoder 1 1 <ESC> K W 0 = Disabled
1 = Enabled
Encoder Step
(hundredths of mm)
0 <ESC> K X Range: 1 to 10000
Output Lines Activation 1 1 <ESC> K N 0 = On Complete Read
1 = After Reading Phase OFF
STATISTICS
Status 1 1 <ESC> K O 0 = Disabled
1 = Enabled
Number of Samples 0 <ESC> K P Range: 5 to 1000
Output Format 1 1 <ESC> K Q 0 = % (on Last Samples)
1 = N/M (on Last Samples)
2 = %+N/M (on Last Samples)
3 = % (on All Samples)
4 = N/M (on All Samples)
5 = %+N/M (on All Samples)