MATRIX 210™ PARAMETERS LIST
21
4
PARAMETER TYPE SEL STRING DATA
Reading Phase OFF 4 11 <ESC> A D 1 = Ext. Trig. Leading Edge
2 = Ext. Trig. Trailing Edge
4 = Main Port String
8 = Auxiliary Port String
16 = Input 2 Leading Edge
32 = Input 2 Trailing Edge
64 = Timeout
128 = Complete Read
256 = Ethernet String
512 = Ethernet IP Input Leading Edge
1024 = Ethernet IP Input Trailing Edge
2048 = Fieldbus String
4096 = Fieldbus Input Leading Edge
8192 = Fieldbus Input Trailing Edge
16834 = ID-NET String
Reading Phase
Timeout (ms)
0 <ESC> A E Range: 17 to 60000
Timeout Counting From 1 1 <ESC> A N 0 = Reading Phase ON
1 = Reading Phase OFF
Acquisition Trigger
(One Shot)
4 7 <ESC> A F 1 = Ext. Trig. Leading Edge
2 = Ext. Trig. Trailing Edge
4 = Main Port String
8 = Auxiliary Port String
16 = Ethernet String
32 = Ethernet IP Input Leading Edge
64 = Ethernet IP Input Trailing Edge
128 = Fieldbus String
256 = Fieldbus Input Leading Edge
512 = Fieldbus Input Trailing Edge
1024 = ID-NET String
First Acquisition Setting
Used
1 1 <ESC> A H 0 = First Enabled
1 = Last Successful
Image Acquisition
Buffer Size
0 <ESC> A L Range: 2 to 300
Code Filter Depth 0 <ESC> A I Range: 0 to 5
Code Filter Selection 1 1 <ESC> A N 0 = Acquisition Counter Threshold
1 = Timeout Threshold
Complete Read
Threshold
0 <ESC> A J Range: 0 to 100000
No Read Threshold 0 <ESC> A K Range: 0 to 100000
Timeout Threshold
(sec)
0 <ESC> A O Range: 0 to 300
(0 = Disabled)
ACQUISITION TRIGGER DELAY (DEPTH: n = 1 to 10)
Status #n 1 1 <ESC> n #n 0 = Disabled
1 = Enabled
Delay Time #n
(x100 s)
0 <ESC> o #n Range: 0 to 100000
NOTE
Special characters <FE
H
> and <FD
H
> must be added after #n in the
programming string to indicate parameter Depth > 9. Refer to paragraph 3.2
for further details.