MATRIX 200™ REFERENCE MANUAL
6
In this layout the data is transmitted to the Host on the TCP/IP Ethern
et interface (CBX500
with BM200/210 Host Interface Module installed). The RS232 auxiliary interface can be used
for reader configuration by connecting a laptop computer running VisiSet™. Host Mode
programming can be accomplished either through the TCP/IP Ethernet interface or the
Auxiliary interface.
In Local Echo communication mode, data is transmitted on the RS232 auxiliary interface
independently from the TCP/IP Ethernet selection.
When One Shot or Phase Mode operating mode is used, the reader can be activated by an
External Trigger (for example a pulse from a photoelectric sensor) when the object enters its
reading zone.
Matrix 200™
1
2
3
BM200/210 TCP/IP Ethernet Interface
Auxiliary Serial Interface (Local Echo) (RS232)
External Trigger (for One Shot or Phase Mode)
Host
Power
CBX500
Figure 86 – BM200/210 TCP/IP Ethernet Interface Point-to-Point Layout