Enter/Exit Programming Mode
264
PowerScan™ PD9530/PBT9500/PM9500
Append Code
This function defines how a scanned barcode interacts with a pre-edited
CODE field, or with a string entered by a preprogrammed FUNC KEY.
Options are:
0. Barcode data overwrites what is written in the CODE field by keyboard
and the
code is transmitted;
1. Barcode data is appended to any text i
n the CODE field and the code is
transmitted;
2. Barcode data is appended to any text
in the CODE field but the code IS
NOT transmitted. Data is transmitted when the enter key is pressed.
$CPWFW00\r
Overwrite always
DEFAULT
$CPWFW01\r
Append and transmit
$CPWFW02\r
Append and don’t transmit