Enter/Exit Programming Mode
162
PowerScan™ PD9530/PBT9500/PM9500
Code 93 Set Length 2
This feature specifies one of the bar code lengths for Code 93 Length Con-
trol. Length 2 is the maximum label length if in Variable Length Mode, or the
second fixed length if in Fixed Length Mode. Length includes the bar code’s
check, data, and full-ASCII shift characte
rs.
The length does not include
start/stop characters. The length can be set from 1 to 50 characters. A set-
ting of 0 specifies to ignore this length (only one fixed length).
Table 21 provides examples for setting Length 2. See page 284 for detailed
instructions on setting this feature.
Table 21. CODE 93 Length 2 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
00 (Ignore This
Length)
07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT CODE 93 LENGTH 2 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
$CC9L2
Select Code 93 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
~
CANCEL
DEFAULT
50 = Length 2 is 50 Characters
Seitenansicht 171