192
Magellan
TM
3300HSi
Example: 'F110123456789112345'.
EAN-13 with Code 128 Supplemental
Check digit must be included in label data and is assumed to be correct
Supplemental data is appended to base label
Prefix must be an ASCII character 'F'- total length including prefix must be greater or equal to 20 (code 128
Supplemental codes are variable length having a minimum of 2 data characters)
Characters immediately following base label must be of the form '8100', '8101' or '8102'
Example: 'F11012345678918100000951'
Code 39
Check character must be included in label data.
Label length including start, stop and check characters and excluding prefix character must meet require-
ments imposed by the main scanner's fixed or variable label length control for this symbology type.
Start and stop characters "*" must be included in label.
Prefix must be an ASCII character '*'.
Example : '**Code 39.TEST*'.
Code 39-Pharmacode
Check character must be included in label data.
Label length including start, stop and check characters and excluding prefix character must meet require-
ments imposed by the main scanner's fixed or variable label length control for this symbology type.
Start and stop characters "*" must be included in label.
Prefix must be an ASCII character 'p'.
Example: 'p*123456789*'.
I 2 of 5
Check character must be included in label data.
Label length including check characters and excluding prefix character must meet requirements imposed by
the main scanner's fixed or variable label length control for this symbology type.
Prefix must be an ASCII character 'i'.
Example: 'i0123456789'.