FIELDBUS CONNECTIONS
53
6
6.3 DEVICENET INTERFACE
The 5-pin male connector is only available in the DX8200A DeviceNet model and allows
connection between the host and the reader:
1
3
2
4
5
Figure 64 - DeviceNet 5-pin Male Connector
DX8200A 5-pin DeviceNet connector pinout
Pin Name Function
2 V + Supply voltage – positive pin
5 CAN_L CAN bus data line – L
1 SHIELD Shield
4 CAN_H CAN bus data line – H
3 V - Supply voltage – negative pin
NOTE
The power supplied on pin V+ and V- is used only
to propagate power to
the section of the DeviceNet board directly connected to the Bus. It is
completely isolated from the DX8200A power which must be supplied on
pin 9, 13 and pin 23, 25 of the 26-pin Main/Aux connector.