SOFTWARE CONFIGURATION
27
4
You will place a code at 3 different points within the scanner’s reading field. For each
point, the scanner records the angle and distance.
You record the X, Y, and Z position of the code. Measure as accurately as possible, as
the scanner will use this data to calculate its position and orientation in 3-dimensional
space, and later to tell the SC6000 the position of codes it reads.
Type measured values for a label position in the proper text fields, and click the Calibrate
button; a yellow icon will inform you of a successful step.
At the end, confirm the procedure with Validate calibration.
NOTE
The PackTrack calibration MUST be executed using a barcode having 1
mm. resolution (test chart).
4.3.4 DX8200A Pack/Track Configuration
DX8200A is pre-calibrated during the production process. This makes it easy and fast to
calibrate the scanner after mounting it into the reading station.