131
Code 93
Defaults
Scanner
Type
Code
Parameter
Description
I.D.#
Accept.
Input
Min
Max
Factory
Laser
2D Imager
Enter 1 for On and 0 for Off
Enable
Enables/disables the Code
93 symbology.
0400 On or Off Off On Off √ √
Enable
Aggressive
Decoding
Enables more aggressive
decoding algorithms to be
used in order to scan hard
to read labels.
0401 On or Off Off On Off √
Minimum
Label
Length
Set the minimum label
length to be less than or
equal to maximum label
length.
0420 01 - 50 01 01 02 √ √
Maximum
Label
Length
This feature specifies the
maximum allowable length
of a Code 93 label.
The length includes check
and data characters.
Maximum Label Length
should be greater than or
equal to Minimum Label
Length.
0421 01 - 50 01 50 20 √ √
Read
Verification
Sets the number of times a
label must be read before it
is transmitted.
0422 01 - 04 01 02 01 √ √
User ID
Specifies the symbology
identifier (if any) that is
sent when parameter Send
Code ID (Index 0025) is
set to 3. ASCII code zero
(null) is used to indicate
that an identifier is not to
be sent for the symbology.
0423
Any
single
ASCII
character
(00 = Off)
‘L’ ‘L’ ‘L’ √ √