SOFTWARE CONFIGURATION
125
7
Image Filter
Sets the filter to be applied to the image before being processed. This parameter can be
used to successfully decode particular ink-spread printed codes (ex. Direct part mark codes).
A different filter can be applied to each Image Acquisition Setting.
The Erode Filter enlarges the image dark zones to increase readability.
Before - No Read
After - Readable
Erode
The Dilate Filter enlarges the image white zones to increase readability.
Before - No Read
After - Readable
Dilate
The Close filter eliminates dark areas (defects) in the white zones of the image.
Before - No Read
After - Readable
Close