Datalogic QS6500BT Spezifikationen Seite 30

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 336
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 29
General Features
20 QuickScan
TM
QS6500/QS6500BT
Scanning/Imaging Features
Scan Mode
Selects the scan operating mode for the imager. Selections are:
Good read off — The trigger must be pressed to activate scanning. The
light source stops scanning when there is a successful read or no bar code
is decoded after the
Imager Timeout has elapsed.
Momentary — The trigger acts as a switch. Pressing the trigger activates
scanning; releasing it stops scanning.
Alternate — The trigger acts as a toggle switch. Pressing the trigger acti-
vates scanning; pressing it a second time stops scanning
Timeout off — The trigger must be pressed to activate scanning, The
imager stops scanning if no barcode is decoded within the time duration
set for the
Imager Timeout period.
•Stand Mode
The imager continuously reads regardless of whether the
trigger is pressed or
Imager Timeout has elapsed.
Seitenansicht 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 ... 335 336

Kommentare zu diesen Handbüchern

Keine Kommentare