DS4600AReference Manual

Seite 2

viiiThe laser light is visible to the human eye and is emitted from the window on the frontof the scanner (Figure A, 2).Warning labels indicating expo

Seite 3 - INSTALLATION MANUAL

ixPOWER SUPPLY- This product is intended to be installed by Qualified Personnel only.- Model DS4600A-XXX0:This device is intended to be supplied by a

Seite 5 - CONTENTS

GENERAL FEATURES111 GENERAL FEATURES1.1 INTRODUCTIONThe DS4600A is a compact laser scanner complete with decoder designed andproduced to be a flexible

Seite 6

DS4600A211.2 DESCRIPTIONSome of the main features of this scanner are given below:• long-range reading• scanning speed 800 scans/sec• completely con

Seite 7 - GUIDE TO INSTALLATION

GENERAL FEATURES31Electrical connection is provided through a cable on the side of the reader; this cableis terminated with a 25-pin connector (see Fi

Seite 8 - GENERAL VIEW

DS4600A411.3 AVAILABLE MODELSThe DS4600A scanner is available in versions that differ in regard to the followingcharacteristics:• Decoding Mode • Spec

Seite 9 - SAFETY PRECAUTIONS

INSTALLATION522 INSTALLATION2.1 PACKAGE CONTENTSVerify that the DS4600A reader and all the parts supplied with the equipment arepresent and intact whe

Seite 10 - Laser diode class label

DS4600A622.2 MECHANICAL INSTALLATIONDS4600A can be installed to operate in different positions. The four screw holes(M4 x 5) on the body of the reader

Seite 11 - POWER SUPPLY

INSTALLATION725.50.221154.5357.32.265.50.2210°5391.545.50.2230.125.50.2235°0.20Figure 4 - Mounting Bracket Dimensionsmminch

Seite 12

DS4600AReference Manual

Seite 13 - 1 GENERAL FEATURES

DS4600A822.3 ELECTRICAL CONNECTIONSDS4600A is equipped with a cable terminated by a 25-pin D-sub connector forconnection to the power supply and input

Seite 14 - 1.2 DESCRIPTION

INSTALLATION922.3.1 Power SupplyPower can be supplied to the scanner through the pins provided on the 25-pinconnector used for communication with the

Seite 15 - GENERAL FEATURES

DS4600A1022.3.2 Main Serial InterfaceThe signals relative to the following serial interface types are available on theinput/output connector:RS232RS4

Seite 16 - DS4600A - XXXX

INSTALLATION112 RTS/CTS HARDWARE HANDSHAKING ENABLED DS4600A USER INTERFACE 7 SGND Main SGND RTS232 4 DCD CTS232 5 DTR RX232 3 TXD TX232 2 RXD Earth G

Seite 17 - 2 INSTALLATION

DS4600A122RS485 Full-Duplex InterfaceThe RS485 full-duplex (5 wires + shield) interface is used for non-polledcommunication protocols in point-to-poin

Seite 18 - 2.2 MECHANICAL INSTALLATION

INSTALLATION132RS485 Half-Duplex InterfaceThe RS485 half-duplex (3 wires + shield) interface is used for polled communicationprotocols.It can be used

Seite 19 - INSTALLATION

DS4600A142The figure below shows a multidrop configuration with DS4600A scanners connectedto a Multiplexer. 1 1 CHASSIS # 1 RTX485+ RTX485- SGND Main

Seite 20 - 2.3 ELECTRICAL CONNECTIONS

INSTALLATION15220 mA Current Loop (INT-24 Accessory Only)When the INT-24 accessory board is installed, the DS4600A is equipped with a20 mA active curr

Seite 21 - 2.3.1 Power Supply

DS4600A1622.3.3 Auxiliary RS232 InterfaceThe auxiliary serial interface is used exclusively for RS232 point-to-pointconnections.The parameters relati

Seite 22 - RS232 Interface

INSTALLATION1722.3.4 InputsThere is an input available on the DS4600A scanner relative to the External Trigger.There are also 2 general purpose inputs

Seite 23 - USER INTERFACE

DS4600AINSTALLATION MANUAL

Seite 24 - RS485 Full-Duplex Interface

DS4600A182 18/6/14 + 19/10/15 - USER INTERFACE DS4600A Signal + 5V VS 9 25 GND Ground V Figure 14 - Input NPN Command Using DS4600A Powe

Seite 25 - RS485 Half-Duplex Interface

INSTALLATION192The electrical features of the inputs are:Maximum voltage = 30 VdcMaximum current = 25 mA.An anti-disturbance hardware filter is implem

Seite 26

DS4600A2022.4 POSITIONINGThe DS4600A scanner is able to decode moving barcode labels at a variety ofangles, however significant angular distortion may

Seite 27 - DS4600A USER INTERFACE

INSTALLATION212The Tilt angle is represented by the value T in Figure 20. Position the reader in orderto minimize the Tilt angle.Figure 20 - Tilt Angl

Seite 28

DS4600A2222.5.1 Point-to-PointIn this layout the data is transmitted to the Host on the main serial interface. HostMode programming can be accomplishe

Seite 29 - 2.3.4 Inputs

INSTALLATION2322.5.2 Pass ThroughPass through mode allows two or more devices to be connected to a single externalserial interface.Each DS4600A transm

Seite 30 - USER INTERFACE DS4600A

DS4600A2422.5.3 RS232 Master/SlaveThe RS232 master/slave connection is used to collect data from several scanners tobuild a multi-sided reading system

Seite 31 - 2.3.5 Outputs

INSTALLATION2522.5.4 RS485 Master/SlaveThe RS485 master/slave connection is used to collect data from several scanners tobuild a multi-sided reading s

Seite 32 - 2.4 POSITIONING

DS4600A2622.5.5 MultiplexerEach scanner is connected to an MX4000 with the RS485 half duplex mode on themain interface.c Main Serial Interface (RS485

Seite 33 - 2.5 TYPICAL LAYOUTS

INSTALLATION2722.6 USER INTERFACERS232 PC-side connections 1 5 9 6 9-pin male connector 13 25 14 1 25-pin male connectorPin Name Pin Name2RX 3 RX3TX

Seite 34 - 2.5.1 Point-to-Point

DATALOGIC S.p.A.Via Candini 240012 – Lippo di Calderara di RenoBologna - ItalyDS4600A Reference ManualEd.: 06/2003ALL RIGHTS RESERVEDDatalogic reserve

Seite 35 - 2.5.2 Pass Through

DS4600A2833 READING FEATURES3.1 ADVANCED CODE RECONSTRUCTIONThe traditional way of barcode reading could be called "Linear Reading". In thi

Seite 36 - 2.5.3 RS232 Master/Slave

READING FEATURES2933.1.1 Tilt Angle for Advanced Code ReconstructionThe most important parameter in Advanced Code Reconstruction is the value of them

Seite 37 - 2.5.4 RS485 Master/Slave

DS4600A3033.2 DECODING CAPACITY IN LINEAR MODEWhen in Linear Reading mode, the number of reads performed by the DS4600A andtherefore the decoding cap

Seite 38 - 2.5.5 Multiplexer

READING FEATURES313If scanning is perpendicular to the direction of the code movement (Figure 30), thenumber of effective scans performed by the reade

Seite 39 - 2.6 USER INTERFACE

DS4600A323If scanning is parallel to the code movement (Figure 31) the number of effectivescans is given by:SN = [((FW-LW)/LS) * SS] - 2These symbols

Seite 40 - 3 READING FEATURES

READING FEATURES333The reading characteristics for the raster versions are given in the table below. Thedistance between the top and bottom scan lines

Seite 41

DS4600A3433.4 READING DIAGRAMSThe following diagrams show the reading distance for barcodes with differentdensities.DS4600A-210X (Long Range) 4 4 12 1

Seite 42 - 3.2.1 Step Ladder Mode

READING FEATURES353DS4600A-200X (Medium Range) 4 2 0 2 10 8 6 4 6 (in) 0 2 6 4 12 (in) 8 10 14 16 18 0 50 100 150 200 250 300 350 400 450 500 550 (m

Seite 43 - 3.2.2 Picket Fence Mode

DS4600A363DS4600A-22XX (Short Range)21015432345(in)01 32106(in)45 7 8902040 6080 100 120140160180200220240260(mm)12010080604020020406080100120(mm)2801

Seite 44 - 3.3 PERFORMANCE

READING FEATURES373DS4600A-22XX (Short Range)4202108646810(in)02 642012(in)810 14161804080 120160200 240280 320360400440480520(mm)24020016012080400408

Seite 45

iiiCONTENTSGUIDE TO INSTALLATION ... vGENERAL VIEW ...

Seite 46 - DS4600A-210X

DS4600A383DS4600A-2X1X (Raster R1) 4 2 0 2 10 8 6 4 6 (in) 0 2 6 4 12 (in) 8 10 14 16 18 0 50 100 150 200 250 300 350 400 450 500 550 (mm)250 200 15

Seite 47 - DS4600A-200X

READING FEATURES393DS4600A-2X2X (Raster R2)4202108646(in)02 6412(in)810 141618050100150 200 250 300 350 400 450 500 550(mm)250200150100500501001502002

Seite 48 - DS4600A-22XX

DS4600A403DS4600A-31XX (Long Range)44121216(in)04 2012(in)8160100 200 300 400 500 600 700 800 900 1000(mm)4003002001000100200300400(mm)24 28 32 36 401

Seite 49

READING FEATURES413DS4600A-30XX (Medium Range)4202108646(in)02 6412(in)810 141618050100150 200 250 300 350 400 450 500 550(mm)250200150100500501001502

Seite 50 - DS4600A-2X1X

DS4600A423DS4600A-32XX (Short Range)4202108646810(in)02 642012(in)810 14161804080 120160200 240280 320360400440480520(mm)24020016012080400408012016020

Seite 51 - DS4600A-2X2X

MAINTENANCE4344 MAINTENANCE4.1 CLEANINGClean the laser beam output window periodically for continued correct operation ofthe reader.Dust, dirt, etc. o

Seite 52 - DS4600A-31XX

DS4600A4455 TECHNICAL FEATURESELECTRICAL FEATURESDS4600A-XXX0 DS4600A0-2XX5PowerSupply Voltage 10 to 30 Vdc 24 VdcPower Consumption max. 6 W 12WSerial

Seite 53 - DS4600A-30XX

TECHNICAL FEATURES455SOFTWARE FEATURESREADABLE CODE SYMBOLOGIES• EAN/UPC • Code 93• 2/5 Interleaved • Code 128• Code 39 • EAN 128• Codabar • Pharmacod

Seite 54 - DS4600A-32XX

DATALOGIC S.p.A.,Via Candini, 240012 - Lippo di CalderaraBologna - Italydichiara chedeclares that thedéclare que lebescheinigt, daß das Gerätdeclare q

Seite 55 - 4 MAINTENANCE

DS4600AReference Manual

Seite 56 - 5 TECHNICAL FEATURES

iv3 READING FEATURES3.3 Performance ... 323.4 Reading Diag

Seite 57 - SERIAL ON LINE

vGUIDE TO INSTALLATIONThe following can be used as a checklist to verify all of the steps necessary forcomplete installation of the DS4600A scanner.1)

Seite 58

viGENERAL VIEWDS4600ADS4600A - 2XXX ModelsDS4600A - 3XXX ModelsFigure ACable with 25-pin ConnectorLaser Beam Output WindowWarning LabelMounting HolesA

Seite 59

viiSAFETY PRECAUTIONSLASER SAFETYThe following information is provided to comply with the rules imposed byinternational authorities and refers to the