Mounting the Scanner
10 Gryphon™ GFE4400
User Interface
The User Interface connection (J2) provides the integrator a means to
monitor scan engine status (LEDs), and offers an additional mechanism
for manually triggering the device.
The user connection (J2) uses a Molex part number, 0527460671,
0.50mm (.020") Pitch FFC/FPC Connector, Right Angle, SMT, ZIF,
Bottom Contact Style, 6 Circuits, Gold Contact Plating. For custom ad-
aptations, the integrator must interface using an FFC (Flat Flexible Cable)
that mates properly to scan engine ZIF connector.
Figure 6. Top view
The assignment of the J2 connector pins are indicated in the following ta-
ble.