DX8200A QUICK GUIDE
15
Minimum Code Height for Omnidirectional Reading (mm)
Conveyor Speed (m/s) 0.5 1 1.5 2 2.5 3
0.25
8 10 12 14 16 18
0.30
9 11 13 15 17 19
0.33
9 11 13 15 18 20
0.38
10 12 14 16 18 20
0.50
13 14 16 18 20 22
0.72
17 18 19 21 24 26
Codabar
Code Resolution (mm)
1.00
23 24 25 26 28 30
Ratio 3:1; Interdigit = Module Size
Table 4
Minimum Code Height for Omnidirectional Reading (mm)
Conveyor Speed (m/s) 0.5 1 1.5 2 2.5 3
0.25
8 9 11 13 15 18
0.30
9 10 12 14 16 18
0.33
9 10 12 14 16 19
0.38
10 11 13 15 17 19
0.50
12 13 14 16 19 21
0.72
16 18 19 20 21 23
EAN 8-13, UPC-A
Code Resolution (mm)
1.00
22 23 24 25 26 27
Table 5
READING DIAGRAMS
Note: x = 0 and z = 0 correspond to the edge of the DX8200A scanner as shown in the figure below.
DX8200A-3X3X (0.25 mm/10 mils)
CONDITIONS
Code = Interleaved 2/5 or Code 39
PCS = 0.90
(in)
0-24-16 -40
(in)
-32 -48
0
-40 -60 -80
(cm)
-30
-20
0
-10
(cm)
-100 -120
-50
-40
30
20
10
50
40
-12
-8
0
-4
-20
-16
12
8
4
20
16
z
x
Kommentare zu diesen Handbüchern