READING FEATURES
4
Leg 1
Leg 2
Figure 65 – DX8200A Scan Legs
NOTE
In the vast majority of systems the x and z data are not necessary. For
these cases set x = 0, z= 0 during the calibration procedure.
4.3 PERFORMANCE
The scan rate is 1000 scans/sec (500 scans on each leg).
Refer to the diagrams in par. 4.4 for further details on the reading features. These diagrams
are taken on various resolution sample codes at a 25
°C ambient temperature depending on
the conditions listed under each diagram.
If standard models do not satisfy specific requirements, contact your nearest Datalogic
distributor, supplying code samples, to obtain complete information on the reading
possibilities.