DX8200A QUICK GUIDE DX8200A General View: Figure A Laser Beam Output Windows1 Mounting Slots 2 Laser Safety Label 3 Figure B Programming Keyp
DX8200A QUICK GUIDE 10 Local Lonworks Networks Large Synchronized Network with DX8200A and DS8100A Scanners Large Synchronized Network Re
DX8200A QUICK GUIDE 11 COMMON FEATURES C-BOX 100 Pinout for DX8200A: The table below gives the pinout of the C-BOX 100 terminal block connectors.
DX8200A QUICK GUIDE 12 Mechanical Installation: DX8200A can be installed to operate in any position. There are 4 slots (dia. 8.5 mm) on the sides
DX8200A QUICK GUIDE 13 Minimum Code Height for Omnidirectional Reading (mm) Conveyor Speed (m/s) 0.5 1 1.5 2 2.5 3 0.25 9 11 13 15 17 19 0.30 10 1
DX8200A QUICK GUIDE 14 Reading Diagrams: Note: x = 0 and z = 0 correspond to the edge of the DX8200A scanner as shown in the figure below. DX820
DX8200A QUICK GUIDE 15 DX8200A-3X1X (0.38 mm/15 mils) CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 0-24-16-40(in)-32 -48 0 -40 -60 -80
DX8200A QUICK GUIDE 16 User Interface: How To Build A Simple Interface Test Cable: The following wiring diagram shows a simple test cable includ
DX8200A QUICK GUIDE 17 LASER LIGHT DO NOT ST ARE INTO BEAM CLASS 2 LASER PRODUCT MAXIMUM OUTPUT RADIATION 1 mW EMITTED WAVELENGTH 630~680 nm
DATALOGIC S.p.A., Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy 05 dichiara che declares that the déclare que le bescheinigt, daß das
DX8200A QUICK GUIDE 2 Technical Features: ELECTRICAL FEATURES (see note 1) VAC models VDC models Supply voltage 110 to 230 Vac 20 to 30 Vdc P
DX8200A QUICK GUIDE 3 SOFTWARE FEATURES Readable Codes Interleaved 2/5 Code 39 Standard Codabar Code 128 EAN 128 Code 93 (standard and full ASCII) E
DX8200A QUICK GUIDE 4 Model Description: DX8200A - 3 X Y ZPower: 0 = VDCOptical Resolution:1 = Medium resolution Communication Type: 0 = Standar
DX8200A QUICK GUIDE 5 Electrical Connections: The details of the connector pins are indicated in the following tables: The DX8200A scanner provides
DX8200A QUICK GUIDE 6 Ethernet Version Harting RJ Industrial® Modular Connector DX8200A 5 HUB / SWITCH 3 4 2 1 6 5 3 4 2 1 6 7 8 7 8 RX+ TX- TX+
DX8200A QUICK GUIDE 7 Network Termination: When building a Lonworks system the network must be properly terminated by positioning the BTK-8102 Lonw
DX8200A QUICK GUIDE 8 Connectivity: Point-to-Point Layout * P.S. (Presence Sensor) connected to External Trigger input. Point-to-Point for S
DX8200A QUICK GUIDE 9 Local Lonworks Networks * P.S. (Presence Sensor) connected to External Trigger input. ** C-BOX 100 modified to accept sca